Even if it looks good, it could be bad. Third guess would be that the connections were not tight on the new motor. 3. loose pipe coming into pump, drawing air around fitting threads IF the shaft does spin freely, yet the breaker trips, check the wiring for wires touching each other or the motor housing, loose wires, broken wires or corroded wires or water in the conduit, surrounding broken wires. What am I doing wrong??? Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. We purchased a Hayward D.E Filter last summer. Then it wouldnt turn back on. But most likely an air leak, either before or after the pump, pool systems are supposed to be mostly air tight, though most are not completely. Well, you first need to inspect it, and if the parts are broken, replace them. Inspect the capacitor (black cylinder, 9 oclock) and the centrifugal switch, (on the end of the motor shaft), for any signs of damage or looseness. New pump, was running fine. I have a Haywood swim pro voyager and it is making a loud vibration noise. We purchased a Hayward Pump SP3220EE and I need to know how Thank you. Additional causes for low water flow in your pump are debris build-up or dirty equipment. Press and hold the diagnostic button for 3 to 5 seconds. Did you figure out your problem? It could also be a bad capacitor, which is like a battery, to start the motor. Never had an issue with the other motors we have had. The water level is good. Its less than 2 wks old. To view these documents, you will need to download the free Acrobat Reader, which gives you instant access to PDF files. When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off! We recently had a makeover of our backyard where we replaced the concrete with pavers and it could very well be the sands and dust (yes, I had to vacuum the pool a couple times to get it clean) that got into the parts that helped speed up the demise of the pump. The pool seems to be bonded,I did find that the Aqua Logic Panel is fed from the main electrical panel has no equipment ground, when I established a ground, the motor shortly after burnt up, heard a little crakling and a pop in the motor housing, and little smoke (the breaker did not trip, until the pump smoked out it seemed to be running fine, with a normal amp load. 2) loose pipe coming into the pump (no sealant, or overheated and slightly shrunk), 3) Loose valve lids or o-rings, air-leaky valves in front of the pump (main drain, skimmer). Hello. Hi Ryan, just use a small flathead screwdriver and wedge it between the cover and motor, and wiggle it back and forth, in a few spots around the edge, and pull off with your other hand. I have removed and tested the capacitor it appears OK I then removed the thermostat to try to access the shaft and turn it with a 7/17 wrench, but the protrusions on the casting and other spring mounted stuff appear to make it impossible to get a grip on the shaft. Loose wiring, or broken wires, or wires nearly touching each other, and arcing. I basically removed my old pump and instalked the new one. Hi Mike, its hard to say not knowing which control system you use. Step 1: With your pump running, double-check the positions of your valves. A leaking shaft seal should not cause your filter pressure to decrease. Tonight, I tried to manually start the filter and all I hear is a click in the mother board. When they fail, they often crack, bulge, leak or smell bad, but not always. The ampage to the pump has been the same since we got the pump 7 years ago and never had this issue before. If the shaft is free turning, but the pump does not turn on, check power connections. our previous pump was a hayward variable. If it is a union valve, cream also on the union nut. I purchased a SP1580X15 Hayward pump July 2016 and began using it this year 2017. If the motor label says 115V/230V it is reversible, but if it says just 230V, Hi Chad, Your salt level is between 2500-2600 parts per million (ppm). Big difference, but other than that, they operate pretty much the same! You must log in or register to reply here. low speed works fine, pump is three years old. iv also replaced o rings and filter basket gasket. Not sure if this is somehow related to the water being heated or maybe air in the pump just guesses. It worked fine just prior to a filter cleaning. The problem lies where the power dies [note to readers: motor cycling is not the same as pump cycling, where the water flow starts and stops, here I am talking about the motor itself starting/stopping], I have a Hayward sp2607x10 pump. Many thanks. Why would the pump and Polaris stop working at the same time? The capacitor is at 9 oclock and the thermal regulator at 12 oclock. Replace with exact MFD number, printed on side. The unit works fine for approximately 4- 6 hours, then the Check Salt and Inspect Cell flashes (salt level on the unit reads 2600 ppm). My pool pump was running fine until I turned it off. Second thought is are the pipes plumbed into the valve correct? For AquaRite, move the switch from auto to off and check all of the readings. I recently took it ofdf to install a new spider gasket and saw no obvious reason for the leak. i know there is a low spead and hit speed switch when i take off the cover but it looks ok. it seems like the contacts get stuck together preventing the pump to turn on? Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). So if the water flow thru the unit is normal then I would next assume a bad flow switch or sensor (depending on what type of pool equipment we are talking about pump, salt cell, heater). how to watch past broadcasts on twitch. The rooms are equipped with a [] | Egypt Travel & Tourism Agency. Hi Javi the capacitor on the motor may have failed. The other rectifier is rated as 18-33 VDC. Went out today to find the lower plastic shroud melting again? Tested the switch on and off and it works as expected. After I installed the ne motor, I pugged it in, started the pump and the breaker tripped. I have a Hayward Perflex DE filter brand new last year. }
. Interesting enough, if I place it in super chlorinate mode, it will produce chorine. Put a meter on the terminal board, and see if the voltage coming into the motor is fluctuating or dropping off, when the motor cycles. The pump keeps kicking off every 24 hours and I turn it back on by hitting filter. Hi, open up the air bleeder on the filter when you open the pump to release the vacuum seal from pump to filter. Please help! I have a S-210 Hayward pool pump and it started spitting sand so I bought a Folding Umbrella Lateral Holder AssY when I dumped the sand out I think 2 of them were broken for a couple of months it seems sand has been dumping in the pool thats why I bought the lateral. Also they winterized the place where the water circulates inside the pool and it wont unscrew so we can let some of the water out and put the original piece back on. Additionally, ensure all o-rings, valves, and gaskets are lubricated and situated in the right positions. I hope new filters fix the problem!!! Hi there. I spent 1 hour one one bolt alone. There is another switch located at 6 oclock called the stationary switch. larger hp motors, are not reversible. Air can enter pressure side if the water is not making it all the way to the top of the filter or chlorinator. If none found, inspect your valve settings, on the equipment pad, and make sure everything is normal, and the cleaner water flow is not being throttled or bypassed. The stickers and labels mean it is WIRED to allow for 230. This issue started immediately after I changed the filter grids on my FNS plus 60 filter. Good morning. i put the hose down the skimmer outlet back to the pool to fill the pipes, still nothing. Hi Leah, good question, and I understand. Inspect for any damage to wires or wire casing. HI, that is usually a weak motor capacitor, which is a battery used to help the motor get up to 3450 RPM quickly. So, if you replaced the handle assembly and valve, aka the Key Assy, item SPX0714BA, and water is still coming out of the backwash line? heres the motor: https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft and the seal: https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2. Anyway, have you checked the cleaner line strainer? I have a Hayward pump for my above ground pool, it is two years old. There was a slight drip coming from a fitting, that I tightened. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. The pump is 18 yrs. Mark. If the salt level is within range, go to Step 3. "
Yes, you can briefly test motors, for a few seconds without water, no problem. Give the cell an acid soak and it should clear the blockage. When I take the lid off the pump hopper I can hear the air releasing, and there cant be any air leaks anywhere as its a new line right from the pump directly into the pool. So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. There are pegs all around that prevent moving the wrench beyond 11 and 12 oclock and because the shaft only has two flat sides we cannot get the wrench from another angle plus there are other pegs. Wire size inside socket too small (cant carry the current). If the motor shaft and impeller is spinning freely (not clogged or bound-up), then remove the rear cover to the motor. Do I need to use lube on the gasket, how much sand should be in the filter? Took out filters and it pumps perfect. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. The motor has all of the same specifications of the Hayward motor that is being replaced, what could possibly cause the motor not ot work? Drying off the terminal board may help, by removing the rear cover. Hi Davy! The higher the pump is elevated above the water level, the more struggles this can cause. Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. Good morning. Thanks A. Ray Davis We have a Hayward ultra pro lx series pump for our above ground pool. Hi if a 2-speed motor only works on low speed, that is usually a loose wire or hi/lo switch. I opened the back and was spinning the rod and it eventually started. Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. Just wired and installed a brand new Century 1 hp pump motor on a Hayward Super pump filter, getting power to the terminals of the motor but motor does not start, shaft spins freely. Is there something special I need to do when first installing the motor? We have tried switching outlets and that sometimes works. Hi Lou, I call that surging, and when a pump does that, and the water level (in the pool) is good, and a stuck skimmer weir is not causing the problem, I would check for an air leak in front of the pump a small void before the impeller that is pulling air in. Could also be low water level in the pool, or a stuck skimmer weir, blocking water flow. Which explains the clicking of the pump. I couldnt believe it..after two weeks and a new pump! I noticed through the basket lid before pump that there was a stream of water(full stream) but to me it didnt seem like enough water being pulled in. Any ideas? It does this everyday and then starts working like normaly for the rest of the day. "@type": "ImageObject",
How To Fix The Problem Thanks in advance for any help you can provide, the pool should be done in the next few days and need to figure out this pump situation. I heard like a crank sound, as if somethings stuck between a propeller if there is. It could be dead. For the leaking underneath, that sounds like the shaft seal SPX1600Z2 or it could be leaking around the plumbing fitting threads, where water exits the pump, and is running down the side of the pump and dripping off the bottom. Water Features, View All It appears to be stuck. Am I doing something simply stupid, or should I call the pool people tomorrow? Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. The AquaTrol is an above ground pool salt chlorine generator that can chlorinate a pool up to 18,000 gallons. But now Im trying to plug it in and it doesnt make any noise at all. Any idea why I would be drawing more current? Pool is ALMOST perfectly clear, BUT, for the life of me, I cannot get pressure to stay strong when vacuuming. Last year the cap that you would remove to clean the filter was becoming more and more difficult to remove and get back on and now I cannot get it back on at all. Fitness View More. I took the lid of the pump basket and cleaned the seal and placed it back on tightly, but there are small bubbles still coming out of the pool jets. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Could also be a loose wire connection, the power wires. Next, check continuity from lead to lead. It is a generic Hayward pump with 1 HP. Remove C/B Assy. We have a Hayward Super Pump 260710 that is 1 hp.The pool was working fine when we opened it 1 week ago except after it would run for 15-20 mins the motor would trip the circuit breaker so we had an electrician replace the motor and check the electrical and that was fine; however, we cant get the pump primed. Indeed, it was the capacitor and as soon as I replaced it ($6) the pump is working like a champ. Pump is 29 years old so wouldnt surprise me if impeller is failing. I would test the voltage at the motor terminal board, very quickly, before the breaker trips, to be sure its between 210V-250V coming in. Hope that helps! Pumps can also leak water from the shaft seal, which can appear to be a housing/seal plate leak, but will leak only directly from the bottom. I have chalked all the connections and lubricated the basket seal. We opened our pool a week ago and havent had a problem until today (May 23. Royal Tulip Beach Resort is located near Port Ghalib, 42 km from Marsa Alam. Good luck! Everything is Primed and ready to go, soon as I put the vacuumin on the skimmer, the pressure stays for about 30 secs then the pressure and water level drop to next to nothing. "identifier": ""
I made sure the basket was seated properly and put grease on the o-ring on the cover and made sure it was tight. But most aboveground pool pumps are 115V, and certainly is if it came with the cord. You could provide a kind of tabletop shade to the motor, but dont enclose it and restrict air flow. },
That is the black cylinder located in the rear of the motor, at 9 oclock. The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Hi George, that is a strange one, because you dont backwash, yet pressure returns to normal, just by shutting pump off for a minute, then restarting? If you see any damage, replace your flow switch. I went out Toto shut it off so I could backwash and add chlorine. thoughts? 4. Is this enough to cause it not to prime or is there an issue with the impeller? I have called a repair company since the pump is under warranty and they told me that it is almost NEVER the pump and therefore if it is something else I will have to pay $89/hour for their serviceso I was hoping to exhaust all other possibilities before coughing up the moneyCan you recommend any tests that I can do? The temperature of the pool water is too high or too low to operate. https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual the first pdf link is the older model H150, the second .pdf link is the newer H150 models, altho it may not make a difference. Sometimes it hums but wont start and other times there is nothing. "url": "https://intheswim.com/",
How are you supposed to move the shaft several revolutions with a 7/16 wrench with all the pegs in the way and the shaft only having two flat sides to get the wrench to lock on to it??? Electrical hooked up by electrician help!! Would the lack of enough sand cause the water to gush out of the top of the filter? If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. "primaryImageOfPage": {
Hi! Look closely at the suction-side (incoming pipes/valves, up to the strainer pot), and shut off pump, watching closely for water spray, or sometimes just a fast dribble. Im not sure how the filters went bad being winterized, but they were way old. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. "@type": "ImageObject",
Step 3: Is your cell clean? In the last couple weeks it started getting louder at various times throughout the day. What would the problem be? WTF! Hmmm, should work? I was attempting to replace shaft seals when something went wrong. "height": "219",
Calling the pool builder for warranty info, too. I turned the gas off to it. Please help! 2. "caption": "In The Swim Blog"
Or very high mineral content (very hard water), or oily substances. Ive checked all my hoses for clogs and skimmer and pump baskets are clean. Ive tried connecting direct from circuit breaker, as well as bypassing with a timer. Any suggestions? ), or the valves that are before the pump. I put a new 1 hp motor on the pump, and new mechanical seal in the pump, problem still the same. Hi Todd, ok I understand check the seal to make sure it is properly seated, and that the spring half is not turned backwards (should be hard plastic side toward motor, soft rubber side toward impeller, in most cases). All Products, View Incorrect size breaker powering the outlet (below 15 amps). It is not just the connection that is leaking, the pump body itself has sprung at least one leak near the neck of the top fitting. Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free. Does the mother board need replacing? I have a Hayward Power-Flo Matrix and seems to be working fine when it is running the pool. Hi Mike, it could be the start capacitor going, or it could be that one of the bearings is not quite perfectly flat, and if the shaft stops rotating at the right spot, it has trouble making the shaft turn, until bumped. If assumed to be the capacitor, get the MFD number printed on it, and find an exact replacement capacitor on our site, or from a local electric motor shop. Or using a Clarifier after vacuuming can also be a solution. Morning , everything was working fine with my Hayward pump. The o-ring should be a very tight fit also, not loose in the groove of the lid. Is there a solution for this problem? What are the amp and volt readings for the new cell? I really dont know how long the motor was running like this when I discover the problem when I discover the problem the motor had already shut off. Secondly, check that there are no air leaks in FRONT of the pump, typically around the pump lid, or on the pipe coming into the pump. What possibly is happening, is that air is being sucked in, possibly from low water level or a stuck skimmer weir, or an air leak in front of the pump (before the pump). Do you believe I have a bad breaker? Yes, if not grounded correctly, the GFCI will trip. You may give Hayward a call, and ask their tech support directly. Thanks in advance for any help. Check the pump lid o-ring or gasket, and be sure the lid is very tight. Any ideas why? I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. . 7. inspect breaker, turn off breaker to pool from house main panel). Second possibility is the pump is too high above water level. And since it was running before (it shut off), its probably not rust. Overheating can be a short across the windings, or it can be other major faults within the motor. If the amps on either reading show zero (0), then you should replace your PC Board. If all is good, there is a possibility that the breaker or GFCI outlet is bad. I check electrical from the panel breaker, to the timer to the circuit breakser to the switch to the outlet, through the wire to the pump and power is getting to the pump. You can plug the pump into a long extension cord and test it with another outlet on the house, to rule out problems with the outlet its plugged into now. I shut the pump down the other night and it will not run. If you program an incorrect cell size, the salt level, amperage, and voltage will not be correct and the system will turn off. 5. He said its drawing 58 amps. There are some pumps that will draw air in thru a faulty shaft seal, which will leak water, dripping below the pump, when the pump shuts off. },
Thanks! From the Hayward Ecostar Owners Manual: the Heat Sink Overheated error indicates that the heatsink on the bottom of the drive has overheated. 6. Hi Larry, valid question. And check that incoming power matches the voltage for the motor, as the motor can be switched to accept 110V or 220V, see wiring diagram on motor label. Copyright 2022 In The Swim. If the water is running down between the pump and motor, determine if its dripping out of the plumbing fitting on top or the shaft seal on the bottom. Did not raise red flags, amature lol. The pump said it came prewired for 230V, but we are running 115V. There isnt a break-in period for these units. The usual spot is the pipe that threads into the pump did you use Teflon tape and/or silicone sealant on the threads? Its half as light as say, flour so we use twice as much. There must be a leak. I replaced the capacitor last year. Hi Marshall, check that the water level is good, and skimmer weirs are not stuck, blocking water flow into the skimmer, both cases cause the skimmer to suck air, which cause the pump to lose prime. Higher horsepower motors are usually only 230V, above 2 hp, but lower hp motors are sometimes reversible, or have the ability to wire either with 110V or 220V, but they will say this on the motor label if they are (reversible) and have a diagram also. GFCI breakers can go bad, but then again, they can be good, and this symptom could be warning you of a potentially unsafe situation. Could be a problem with the centrifugal switch, located dead center on the rear of the motor, or the stationary switch, located beneath it, and contacting each other in the center. When pumps dont run for a long time, they are susceptible to rust forming in between the stator and rotor. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. Any ideas? anyway I digress. Found this blog, followed the instructions by removing the capacitor and thermal overload, turnied the shaft with a 7/16s. Hi Brian, is this a DE filter? When I go to backwash the filter pump shuts down. Hi Tim, If Assy A has a bad motor (test it? On initial trial for ignition. First time pool owner (obviously dont know what we are doing). Hi Shelly, sounds like maybe the board got wet, or there is a loose connection, or power supply issues. Silicone lube can also be used, but dont use petroleum based lubes that can eat the rubber. I have a D.E. Search our blog for shaft seal replacement, if so. hayward salt cell plumbing diagram blue essence 20 manual hayward aquarite troubleshooting guidehayward salt system troubleshooting aqua rite diagnostic codes Blue essence salt chlorine generator owner's manual Salt Chlorinator Cell Replacement, Salt Water System Parts, Pool Light, Pool Alarm, Pool. Thanks. Motors are hot normally, 140 degrees or so, but if it shuts off and then resets and turns on again after 15-20 mins, it could be overheating, from voltage problems, loose connections, motor board, switch or capacitor wiring problems, or internal winding shorts. The pump should really be on its own breaker if possible. When I turned the pump on it is very loud and the pump is not moving water. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. If control input data is corrupts, the heater will shut down and lockout. Second thing is to see if the Motor Shaft Spins Freely, rust can develop which can bind up a motor. I would start by lubing the pump lid o-ring with pool lube, and trying to tighten the lid a bit more if you can. Armstrong Human Resource Management 13th Edition Pdf, If it does make a humming or buzzing sound briefly and trips the breaker, check that the shaft rotates the impeller freely, and if so, replacing the capacitor is usually the fix. {
To Become a Customer please Click Here > Skip to the end of the images gallery Skip to the beginning of the images gallery HAYWARD SALT CHLORINATOR SYSTEM 35K - BLUE ESSENCE-35 Sku: BLUE ESSENCE-35 Be the first to review this product I have a Hayward pump that will backwash but nothing else. An excessive temperature difference between the two thermistors (5 F or more) or an out of bounds condition on both sensors (less than 10F or greater than 180F) will result in the error code. I turned it on and it ran fine for about one hour.